One Shot Universal Liquitreat 100

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners
Category

Boiler and Feed Water treatment specialized chemical is a well - balanced blend for boiler water treatment products, Resulting in a scale and corrosion control by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.

The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. 

Application

The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-025 solution by dilution with water. RXSOL-50-5001-025 is strongly alkaline.RXSOL-50-5001-025  is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.

Dose

Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose.

Used in low pressure and auxillary boilers

:::::::::::::::::::::Alkalinity  TEST FOR BOILER & COOLING WATER ::::::::::::::::::::::::

REAGENT & APPARATUS
:
Reagent:  RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER

PROCEDURE for p-ALKALINITY  test ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3

RESULT  : Each DROPS is equivalent to  25 PPM of Alkalinity .

NOTE :    p-Alkalinity VALUE  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

        

PROCEDURE for p-ALKALINITY  & TOTAL ALKALINITY ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3
  4. Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .
  5. AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish  pink  colour develop.

RESULT  : Each DROPS is equivalent to 25 PPM of Alkalinity .

NOTE :    p-Alkalinity ppm CaCO3VALUE ( A )  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

Total Alkalinity ppm CaCO3VALUE  =  A +  { 25 X ( Total Number of DROPS of TK9 , during 5th step  )}

 

 

 

NUMBER OF DROPS OF TK9                                                                                     p-Alkalinity as CaCO3                                

                        1 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>25
                        2 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>50

                        3 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  75
                        4 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  100

                        5 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 125
                       10 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  250

                       20 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  500
                       30>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >750

                       40 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  1000
 

Optimum Result    :   p-Alkalinity  level  is between 100 to  150 PPM is suggested.

 if  p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.   

For Below  50 ppm  , Dose ½ Ltrs of RXSOL-50-5001-025 for 1000 Ltrs of  BOILER WATER , to maintain p-Alkalinity level 100 ppm.

Refill pack : REPLACEMENTS  

TK7   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK8   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK9   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

 

How to dose One Shot Universal Liquitreat to your BOILER?

Continuously dose diluted RXSOL One Shot Corrosion treatment  to the feedwater line downstream of the feedwater recirculation offtake, which returns water to the hotwell or cascade tank. If there is no feedwater recirculation, dose continuously to the feed pump suction. A less preferred method is a gravity feed flow meter arrangement because volatiles can be lost as recirculated water is returned to the hotwell or cascade tank. If a gravity feed flow meter arrangement is used, the dosage point should be to the hotwell or cascade tank. The chemical feed line should extend below the normal water level (approximately 1 meter) and as close to the feed pump suction as possible.

RXSOL One Shot Liquitreat for BOILER treatment should be diluted with good quality distilled water or condensate in the dosage tank and dosed continuously over a 24-hour period in keeping with system demands. Daily dosage will depend on system capacity, purity and quality of condensate returns and the quality and amount of makeup to the system. Good quality distilled makeup water is recommended for use with RXSOL One Shot Liquitreat 100 treatment. The recommended initial dosage of RXSOL One Shot Universal Liquitreat 100 treatment is 2.5 to 5 liters per ton of water in the boiler system. Once the system has been initially dosed and is in operation, the daily hydrate alkalinity test result determines the necessary dosage.

Technical specifications

Boiler Water Treatment products

Characterisitcs:

  • Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
  • Provides optimum conditions for hardness control to function.
  • Neutralizes acid conditions.
  • Will assist in keeping silica in suspension.
  • Simple test to determine level of treatment.
  • Can be used in boilers of all pressures.
  • Can be used as a neutralizer after acid cleaning operations
  • Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
  • Dispersant action suspends sludge and sediment particles for efficient blow down.
  • Oxygen scavenging for optimum protection.
  • Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
  • Fast action due to catalyst.
  • Simple test to determine level of treatment.
Note

Features of using RXSOL One Shot Universal Liquitreat 100 for your BOILER

  • Complete low-pressure boiler water treatment
  • Simplified feed and control

Benefits to your BOILER

  • Eliminates the need for multiple product inventory
  • Minimizes oxygen and low pH corrosion in condensate and steam systems
  • Conditions sludge
  • Prevents scale and corrosion in the boiler
  • Promotes efficient heat transfer
  • Operator ease
Remarks / Precaution

Basic Boiler System Schematic

Below is a summary of problems associated with the common impurities in water and solutions to each problem.

List Of Problems Caused By Impurities In Water

Impurity (Chemical Formula)

Problems

Common Chemical Treatment Methods

Alkalinity (HCO3-, CO32- and CaCO3)

Carryover of feedwater into steam, produce COin steam leading to formation of carbonic acid (acid attack)

Neutralizing amines, filming amines, combination of both, and lime-soda.

Hardness (calcium and magnesium salts, CaCO3)

Primary source of scale in heat exchange equipment

Lime softening, phosphate, chelates and polymers

Iron (Fe3+ and Fe2+)

Causes boiler and water line deposits

Phosphate, chelates and polymers

Oxygen (O2)

Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)

Oxygen scavengers, filming amines and deaeration

pH

Corrosion occurs when pH drops below 8.5

pH can be lowered by addition of acids and increased by addition of alkalies

Hydrogen Sulfide (H2S)

Corrosion

Chlorination

Silica (SiO2)

Scale in boilers and cooling water systems

Lime softening

Packing sizes
ONE SHOT Boiler water treatment chemical products to control scale and corrosion inhibitors, oxygen scavengers, and sludge conditioners available in 25, 50, 210 Ltr HMHDPE Barrel.
MSDS

 

Product Name : RXSOL-50-5001-025
Product Type :

One Shot Universal BWT

 Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock point : Kandla, Mumbai, Kolkata, Visakhapatnam, Chennai, Fujairah

Phone : +91 22 27815540 / 41 / 42
Fax : +91 22 2781 1318 ::: AOH :0091 9821214367
Email : mail@rxmarine.com

 Chemica Name

 Concentration

 CAS Number

EC Number

 R Phrases*

 Symbols

 Potassium   hydroxide         

 3-5

 1310-58-3

215-181 

 22-35

 C

 Tripotassium phosphate

 1-5

 7778-58-3

231-907-1 

Hydrazine 6 - 7 302-01-2      
MORPHOLINE 10-12 110-91-8      
2-Acrylamido-2-methylpropane sulfonic acid 5-7 15214-89-8      

*See Section 16

Odour

Odourless

Appearance

Liquid, colour less to yellow, soluble in water

Contact with eyes

Corrosive to eyes, Can cause damage to the eyes

Contact with skin

Causes burns(R34)

Inhalation

No information available but must be considered harmful

Ingestion

Harmful if swallowed(R22)

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash withsoap and water. Seek medical advice if necessary.

Contact with eyes

If substance has got into eyes, immediately wash out with plenty of water for at least 15minutes Irrigate eyes thorough lywhilst lifting eyelids   Obtain immediate medical attention.Continue flushing with water until medical help arrives.

Ingestion

Do not induce vomiting Never give anything by mouth to anunconscious person.Give water or milk to drink Obtain immediate medical attention.

Inhalation

Inhalation is unlikely to occur Seek medical attention if ill effects occur.

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible)(S45) When in doubt orsymptoms persist, seek medical attention.

-  Non combustible
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

Personal Precautions

Wear protective clothing as persection 8.

Environmental Precautions

No special precautions are required for this product.

Clean Up Actions

Absorb spillageininert material and shovelup.Ventilate the area and wash spill site after material pick-up is complete.

Special Precautions

Wear protective clothing as persection 8.

Handling

Wear protective clothing as persection 8 Eye wash bottles should be available Avoid contact with skin and eyes(S24/25)

Storage

Keep only in the original container in a cool, well ventilated place(S3/9/49).Keep container tightly closed(S7)

Exposure Limits

TLV(TWA)2mg/m3(Potassium hydroxide)

Exposure controls

No special precautions are required for this product

Occupational exposure controls

Wear suitable protective clothing,including eye/face protection and gloves(plastic or rubbera recommended)

Odour

Odourless

Appearance

Liquid, colour less to yellow, soluble in water

pH

13at 100%concentration

pH9.5

11at 0.2 %concentration

Boiling point &gt

100°Cat 760mm/Hg

Vapourpressure

not known

Vapourdensity

not applicable

Freezing point

0°Cat 760mm/Hg

Soluble in water

Completely

Specific gravity

(water=1)1.135

-  This article is considered stable under normal conditions
-  Avoid over heating, Keep away from frost
-  In compatible with acid
-  See Section 5

Toxicological information

No experimental data available

Inhalation

In halation is unlikely to occur

Contact with skin

Prolonged skin or eye contact may cause chemical burns

Contact with eyes

Prolonged skin or eye contact may cause chemical burns

Ingestion

The ingestion of significant quantities may cause burning sensation

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

May cause acute effects in the aquatic environment

Mobility

Completely soluble in water

Persistence and Biodegradability

Degrades by hydrolysis

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant.

Other Adverse Effects

No environmental problems are expected when the product is used / handled correctly. In its intended use, the product will not be released into the environment. Presents little or no hazard to the aquatic environment

Classification

EUWasteclass: 06.02  This material and/or its container must be disposed of as hazardous

 Disposal considerations

Do not discharge into drains or the environment,dispose to an authorised waste collection point Disposal should be in accordance with local, state or national legislation

Proper Shipping Name
UN        
  Proper Shipping Name Potassium hydroxide, solution    
  UNNo 1814    
  Hazard Class 8 PackingGroup: III
Road/Rail(ADR/RID)
  Proper Shipping Name

Potassium hydroxide, solution

   
  ADR UN No 1814    
  ADR Hazard Class      

Sea(IMDG)

  Proper Shipping Name Potassium hydroxide, solution    
  IMDG UN No      
  IMDG Hazard Class 8 IMDG PackGroup.: III
  IMDG EmS F-A, S-B IMDG subrisk

N/A

  IMDG Labels 8 IMDG Flash point:

N/A

Air(ICAO/IATA)

  Proper Shipping Name Potassium hydroxide, solution    
  ICAO Un No

1814

   
  ICAO Hazard Class 8 ICAO Packing Group. III
  ICAO subrisk

N/A

ICAO Labels 8, CAO
  ICAO Flash point

N/A

   

DOT/ CFR (US Department of Transportation

  DOT Proper Shipping Name Potassium hydroxide, solution    
  Hazardous Material potassium hydroxide    
  Hazard Class 8 Identification Number UN1814
  Product RQ (lbs) 1000 DOT subrisk

N/A

  DOT Labels 8 DOT Flashpoint:

N/A

 RiskPhrases

Causesburns (R34)

 SafetyPhrases

In case of contact with eyes, rinse immediately with plenty of water and seek medical advice(S26).Wear suitable protective clothing, eye/face protection and gloves(S36/37/39).In case of accident or if you feel unwell, seek medical advice immediately(show the label where possible)(S45)

Text of Rand Sphrase codes used in this safety data sheet:-R22: Harmful if swallowed;R35: Causes severe burns.The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product interms of safety requirements and does not signify any warranty with regard to the product's properties .The data given here only applies when product used for proper application(s). The product is not sold assuitable for other applications-usage in such may cause risks not  mentioned in this sheet. Donot use for other application(s) without seeking advice from manufacturer

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@kolkatachemical.com