Hydrocarbon Remover HCF

Home / Products / Tank Cleaner / Hydrocarbon Remover HCF
IMPA / ISSA CERTIFIED CHEMICAL FORMULATION

Hydrocarbon Remover HCF

Tank Cleaner Hydrocarbon Remover HCF
Express Kolkata & Haldia Port 2-4 Hr Berth Delivery
Tank Cleaner
Part No. / SKU: RXSOL-20-2008-210

For removal of traces HYDROCARBONS from tank, After cleaning of TANKS from solvent base tank cleaning materials . when possibilities of next cargo will contaminate with hydrocarbon.

Available Packaging:
5, 10, 20, 25, 50, 210, and also available in 1000 Ltrs IBC TANK. The remarkable things about this product are free from any ALKALI materials which is causing a Greasy layer on contact with the Fatty Acid of Veg and animal oil. HCF is neutral as it is clear from the name, Its neutral nature easily emulsifies oil residue without the formation of grease during cleaning hrs.
Ready Port Stock 25L, 210L Drums & 1000L IBC
IMPA / ISSA Standard MARPOL Compliant Formulations
ISO 9001:2015 QA TDS, MSDS & COA Available

Application & Uses

Neutral HCF supplier and stockist at all Indian and UAE - Middle East Coastal. HCF Neutral chemical importance is to emulsify vegetable oils and animal oils and fats residue with less foaming effect. Chemically if you can understand oil and fat which contain FATTY ACID while the general cleaner is alkaline in nature which is resulting greasy mass oncoming contact with Fatty Acid and Alkali cleaning material. To avoid the formation of GREASE like substance inside the tank, it is very important to take care of an alkaline cleaner with such cargo. On the other hand HCF Neutral ( free from any kinds of alkali mixture ) emulsifying oils particle and makes water soluble to remove from zinc-silicate coated tanks surface.

Dosage & Directions for Use

APPLICATION, FEATURES & BENEFITS
Completely miscible with sea water and fresh water.
Suitable for use on zinc-silicate coatings and most common metals.

Note : Limited application on epoxy coatings. The maximum concentration is 10% and a maximum temperature of 60°C.

Technical Specifications & Properties

Appearance Physical Status (20°C) : Liquid
Color : Clear colorless
Odour : Soft
pH (in %1 solution ) : 7.0-8.0
Density : 1.00-1.10 gram / cm3
Solubility in Water : Completely. 

Recommended Industrial & Shipboard Areas

Question : How to clean veg oil ? 

Answer   : Following step can be follows to clean VEG OIL...
Step 1
Don't expose empty tank in air. Try to keep cool temperature inside the tank. Remove any remaining oil residue by gravitational and manual stripping, If possible Dampen a soft, clean cloth or rag under cool to room temperature water. Wring the cloth. The cloth should be damp, not dripping wet.
 
Step 2
If posible Lay the dampened cloth over the vegetable oil. Push downward to absorb as much oil as possible. Do not rub or wipe the oil. Lift the cloth.
 
Step 3
Spray and Sprinkle Hydrocarbon Remover HCF over any remaining vegetable oil. HCF cleaner will emulsify the oil, Allow the product to complete reaction for approximately an hour. 
 
Step 4

Then follow genreal tank cleaning manual of SHIP. Common addopted method for tank cleaning is as follows :::

Spraying Method:-
Using HCF as delivered in drums, spray onto areas where residue remains following rough washing leave for 10-45 minutes (but do not allow to dry), then butterworth at maximum pressure and warm water 60oC for at least 3 hours, checking that there is no foam remaining in the final stages.  Inspects tanks(s) and if desired result has been achieved fresh water rinse and dry.
**Make sure to take all safety precautions are followed when handling / spraying HCF**
                  
Re-circulation Method:–
Fill tank with fresh water and heat up to warm 50oC .  IF a drop line is available on the tank line system, then start to circulate the water and add the required amount of Caustic flakes and HCF to make a 2.5% solution.  A stronger solution can be made, but be advised that too much Caustic and too high temperature will result in white powder all over the tank.  Under normal circumstances, between 2.5% and 4.5% will be sufficient strength.  If there is no drop line, then lower butterworth hoses into the tank from the pump stack header without machines attached and circulate through these hoses while you fill the solution material. 
 
                                             * Use a strainer at the pump stack when circulating any solution.*
 
Step 5
Once clean, use a dry, clean towel or rag to dry the area. Or keep tanks ventelated.

Product Description & Chemical Profile

Hydrocarbon Remover HCF This product is very common to use for removing of  traces  HYDROCARBONS from tank,  After cleaning of TANKS from solvent base tank cleaning materials hydrocarbon may still be left on tank surfaces. with Hydrocarbon Remover HCF is very effective to remove animal and vegetable oils, petroleum products residues from tank surface.

For removal of traces  HYDROCARBONS from tank,  After cleaning of TANKS from solvent base tank cleaning materials . when possibilities of next cargo will contaminate with hydrocarbon.

Kolkata & Haldia Port Logistics Desk

Need pricing, bulk volume, or vessel delivery today?

Send us your required quantity, chemical grade, delivery location, or vessel IMO number. Our technical chemical supply team replies within 1 hour.

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote chemicalkolkata @ gmail.com