Scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture , To increas usable life of cleaned equipment , it is safe and effective way to remove scale deposits
Category

Scales are very damaging to the boiler because they interfere with the heat transfer and can lead to overheating and eventually, boiler rupture , To increas usable life of cleaned equipment , it is safe and effective way to remove scale deposits from all types of water-cooled and water-heated equipment. This descaler specifically formulated and developed to rapidly clean mineral scale from passages in water-cooled or heated equipment. It improves Plant Efficiency, Lowers Cost, Conserves Energy, Decreases Down-Time.
It does not contain toxic cresols or other tar oils that Require SARA Title III, Section 313 spill loss or disposal.

Do not use concentrated 1008 on aluminium surfaces

Uniqueness of 1008 :: --
RXSOL 1008 Descaler has the ability to dissolve approximately 1.5kg of calcium carbonate scale per gallon in concentrated form. It does not need to be heated up during cleaning. The uniqueness of this Descaler allows you to clean some equipment while still in operation utilizing a minimum of your own personnel.

Application
Low Foaming Solution. Safely removes scale from cooling towers, pipes, Boilers, Calorifiers, Heat exchanges, diesel engine cooling system, Condensers, Evaporators & other types of equipment where rust & scale form without system shutdown
 
It Effectively Removes Scale, Heavy Slime and Algae from surface. RXSOL 555 is an inhibited phosphoric acid descaler which is much safer and non-fuming. Also  safe on paint.
Dose

RXSOL-11-1008-020  is mixed with fresh water 3 to 20 percent depending on deposition of scaling.

The most effective method is circulation for large systems or components like boilers, evaporators, condensers, heat exchangers and generally closed systems that have the capability to circulate at a temperature of approximately 40-60°C, for 6-12 hours and solutions of 5-40% of RXSOL-11-1008-020 in water. Keep in mind that the strength of the solution is analogous to the degree of deposition of scale .
In case of small components , the soak method in an immersion bath can be used.


If the equipment to be cleaned is contaminated by oil, grease, sludge or carbonized oil, then first of all clean the system with degreaser  RXSOL-10-1005. RXSOL-11-1008-020 should be mixed with fresh water to form a solution of 10-30%, depending on the extent of scaling. After using RXSOL-11-1008-020 ,  

PRECAUTION :::it is essential to thoroughly rinse all metal surfaces at least once with a 0.5% solution of  RXSO-20-2005  in fresh water. This solution should be circulated for 2-4 hours or until an acceptable pH value is obtained. This will neutralize any remaining acidity & passivate steel surfaces.

RXSOL-11-1008-020 should not be used on Aluminium, Zinc, Tin, or any Galvanized Surfaces for which a special grade cleaner should be used. Chemical Cleaning Module Rx cleansers has developed a 280 litres capacity cleaning module, primarily designed for use with chemical acid solvents for descaling boilers, calorifiers, heat exchangers & other types of equipment where rust & scale form RXSOL-11-1008-020 Boilers, See Rx cleansers Practical Application Manual

Technical specifications

 

Automotive - Closed Circuit Cooling, Dynamometers, Extruders, Molders, Radiators, Welders

Bottling - CO2 Generators, Heaters, Exchangers, Rinse Tanks, Sterilizers, Washers

. HOUSE HOLD - Dissolves hard and old lime scale deposits from your appliances. It extends the life of the appliance and saves running cost. It can be used in appliances such as Washing Machines, Dish Washers, Geysers, Steam Iron, Coffee Makers, Bath Tubs, Bathroom Fixtures etc.

Buildings - Chillers, Cooling Towers, Pipework

Chemicals - Dryers, Extruders, Kettles, Mixers, Reactors, Scrubbers, Vacuum Pumps

Food - Condensers, Ice Machines, Kathabars, Refrigeration Equipment, Steam Tables

Manufacturing - Chillers, Compressors, Furnaces, Quenchers, Vacuum Pumps

Metals - Bearings, Castings, Fans, Hearth & Vacuum Furnaces, Shelters, Sprays

Mining - Bearings, Conveyors, Filters, Presses, Process Lines, Radiators

Paper- Calendar Mill Rolls, Caustic Lines, Scrubbers, Compressors, Liquor Tanks, Pulverizers, Vacuum Pumps

Pharmaceutical- Exchangers, Loop Systems, Kathabars, Pumps, Reactors, Stills, Sterilizers

Refinery - Compressors, Converters, Crackers, Exchangers, Piping, Pumps

Rubber/Plastics - Banbury Mixers, Calendar & Mill Rolls, Extruders, Injection Molders, Molds, Temperature Control Units, Throat Coolers, Towers, Tubers

Steel - Bearings, ConCast Units, Generators, Hearths, Spangle Units, Furnaces

Textile - Air Washers,Compressors, Condensers, Exchangers, Extruders,Towers

 

Boilers

Condensers

Filters

Heat Exchangers

Kettles & Tanks

Pipelines

Pots

Reactors

Steam Jackets

Bath Rooms and Showers

Metal Processing and much more!


 

Applications


  Automotive

  Bottling

  Chemicals

  Food

  - Closed Circuit Cooling

  - Dynamometers

  - Extruders

  - Molders

  - Radiators

  - Welders

  - CO2 Generators

  - Heaters

  - Exchangers

  - Rinse Tanks

  - Sterilizers and Washers

  - Dryers

  - Extruders

  - Kettles

  - Mixers

  - Reactors

  - Scrubbers

  - Vacuum Pumps

  - Condensers

  - Ice Machines

  - Kathabars

  - Refrigeration Equipment

  - Steam Tables

  Manufacturing

  Metals

  Mining

  Paper

  - Chillers

  - Compressors

  - Furnaces

  - Quenchers

  - Vacuum Pumps

  - Bearings

  - Conveyors

  - Fans

  - Hearth & Vacuum Furnaces

  - Shelters

  - Sprays

  - Bearings

  - Conveyors

  - Filters

  - Presses

  - Process Lines

  - Radiators

  - Calendar Rolls

  - Mill Rolls

  - Caustic Lines

  - Scrubbers

  - Compressors

  - Liquor Tanks

  - Pulverizers

  - Vacuum Pumps

  Pharmaceutical

  Refinery

  Rubber & Plastics

  Steel

  - Exchangers

  - Loop Systems

  - Kathabars

  - Pumps

  - Reactors

  - Stills

  - Sterilizers

  - Compressors

  - Converters

  - Crackers

  - Exchangers

  - Piping

  - Pumps

  - Banbury Mixers

  - Calendar & Mill Rolls

  - Extruders

  - Injection Molders

  - Molds

  - Temperature Control - Units

  - Throat Coolers

  - Towers and Tubers

  Bearings

  ConCast Units

  Generators

  Hearths

  Spangle Units

  Furnaces

  Textile

  Utilities

  Other Applications

   

  - Air Washers

  - Compressors

  - Condensers

  - Exchangers

  - Extruders and Towers

  - Boilers

  - Turbines

  - Transformers

  - Cooling Towers

  - Air Compressors

  - Hydrogen Coolers

  - Lube Oil Heat Exchangers

  - Ball Mills

  - Demisters

  - Evaporators

  - Locomotives

  - Absorption Units

  - Diesel Generators

  - Induction Furnaces
Note

 After using  RXSOL-11-1008-020, sense all metal surfaces with 0.5 percent of  RXSOL-10-1005, at least 2-4 hour , up to neutral of PH value.

• Fast and effective scale remover.
• Soft on ferrous metals.
• Removes water scale & rust from boilers/diesel engine & other cooling system
• As well as from condensers, evaporators, & heat exchangers etc

 

Why Use RXSOL Descaler?

  • It is a safe , economical concentrated  chemical to be used on the waterside of heat transfer equipment.
  • You do not have to heat RXSOL 1008 .
    RXSOL 1008  is safer for the employees to use than other acid products.
  • Your equipment will be cleaned in only hours without disassembling any part of the equipment. Equipment can also be cleaned without any down time (cleaning on the run).
  •  Cleans down to the original surface without pitting.
  •  RXSOL 1008 is safe on copper, copper-nickel, bronze, brass, iron, stainless steel and rubber.
  •  RXSOL 1008  will extend the usable life of your equipment, especially when used as a part of a regularly scheduled preventative maintenance program.
  •  Removing the scale build up allows your equipment to operate more efficiently with less down time.

India's largest scale claner manufacturer with multi location stock point. DESCALING Chemical manufacturer and supplier  in Kolkata, Mumbai, Surat, Gandhidham, Vizag, Chennai, Dubai, Fujairah...

Packing sizes
20, 25 ltr., 50, 210 ltr. packing of descaler materials available with us.
MSDS

Product Name RXSOL-11-1008-050
Product Type DESCALING LIQUID
Revised Dat 30-04-2019

Company Details:

RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA

Stock Point : Kolkata, Kandla, Chennai, Mumbai, Kandla, Fujairah, Visakhapatnam, Muscat, Nairobi Kenya, Canada

Phone +91 22 27815541 / 42
Fax +91 22 2781 1318 :::AOH :0091 9821214367
Email mail@rxmarine.com
Website www.rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols

Chlorous Acid

20-40

7647-01-0

 231-595-7    

34, 37

C

Corrosion Inhibitor

5-10

NA 

 NA

NA 

 

Phosphoric acid 32% 7664-38-2 231-633-2 34 C
Oxalo compound Mixture 6-8% ----- -------- ---  
Acetic Acid 5-6% 64-19-7 200-580-7 36-38 C

                      

*See Section 16

corrosive

Corrosive

Odour

Strong smell of hydrogen chloride

Appearance

Liquid, pale yellow, soluble in water

Contact with eyes

Can cause damage to the eyes

Contact with skin

Prolonged skin or eye contact may cause chemical burns

Inhalation

Causes  severe  irritation,  May  cause  breathing  difficulty

Ingestion

Not regarded as a potential route of exposure.,Causes burning sensation  

 

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. Then wash with soap and water When in doubt or symptoms persist, seek medical attention. Contaminated clothing should be laundered before reuse 

Contact with eyes
 

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes. Irrigate eyes thoroughly whilst lifting eyelids Seek. immediate medical attention. Continue flushing with water until medical help arrives. 

Ingestion

Never make an unconscious person vomit or drink fluids Give plenty of water to drink Do not induce vomiting Seek immediate medical attention 

Inhalation

Remove patient to fresh air Keep warm and at rest, in a half upright position. Loosen clothing. When in doubt or symptoms persist, seek medical attention.

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) (S45).

-  Non combustible.
-  Smoke from fires is corrosive, Hydrogen chloride may be formed.
-  Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions.
-  Substance evolves toxic fumes, wear self-contained breathing apparatus.
-  Use water spray or fog to knock down and absorb corrosive fumes.

Personal Precautions

Wear protective clothing as per section 8 Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback. 

Environmental Precautions

Do not allow to enter public sewers and watercourses.

Immediate Actions

Use appropriate containment to avoid environmental contamination (S57).

Clean Up Actions

Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. 

Special Precautions

Wear protective clothing as per section 8 Avoid release to the environment. Refer to special instructions/Safety data sheets (S61) Vapours are heavier than air and may travel considerable distances to a source of ignition and flashback.

Handling

Avoid contact with skin and eyes (S24/25).Do not breathe vapour/fumes (S23).Eyewash bottles should be available.Wear protective clothing as per section 8.Ensure adequate ventilation.In use, may form flammable/explosive vapour-air mixture (R18).

Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49). Keep in acid store.

Exposure Limits

TLV (TWA) 20 ppm, 122 mg/m3 (1,2-Dichlorobenzene).

Exposure controls

The undiluted product must not be used in a confined space without good ventilation.

Occupational exposure  controls

Wear approved respirator if exposure likely to exceed MEL/OES  Wear goggles giving complete eye protection Wear suitable protective clothing, including eye/face protection and gloves (neoprene or nitrile  are recommended).

gloves                suit                visor

Gloves                       Suit                          Visor

Odour

Strong smell of hydrogen chloride

Appearance

Liquid, pale yellow, Soluble in water

PH

1.5 at 100 % concentration

Boiling point

~ 100 °C at 760 mm /Hg

Vapour pressure

105.5 at 20 deg C

Vapour density (air = 1)

1.26

Freezing point~

30 °C at 760 mm/Hg

Completely soluble in water

Specific gravity (water=1)

1.16

Non combustible 

-  This article is considered stable under normal conditions, May cause rubber to swell
-  Avoid overheating
-  Incompatible with strong oxidizing substances, Contact with alkaline earth metals may form explosive gases, Contact with alkali metals may form explosive gases
-  See Section 5

Contact with skin

In cases of severe exposure, redness and irritation may develop 

Contact with eyes

Causes irritation

Ingestion

May cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

This product does not contain ingredients which are classified in the EU as dangerous for theenvironment. 

Mobility

Completely soluble in water .

Persistence and Biodegradability

Its main ingredients will either dissolve rapidly and dissociate in water or are readily/inherently  biodegradable.

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant. Other Adverse Effects No environmental problems are expected when the product is used / handled correctly. 

Classification 
 

This material and/or its container must be disposed of as hazardous waste EU Waste class Disposal considerations Do not discharge into drains or the environment, dispose to anauthorised waste collection point Disposal should be in accordance with local, state or national legislation.

Proper Shipping Name:
UN        
  Proper Shipping Name: Hydrochloricacid, solution    
  UN NO.

1789

   
  Hazard Class 8 PackingGroup II

Road/Rail(ADR/RID)

  Proper Shipping Name

Hydrochloric acid, solution

   

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@kolkatachemical.com