This is most common Oxygen Treatment Scavanger used to effectively remove dissolved OXYGEN from your feedwater. Other grades of 5006 has its own advantages depending on your system and personal preferences ) By the presence of dissolved oxygen in water system , corrosion and pitting caused on metal surface. RXSOL 5006 is a specially formulated and powdered materials. which, when added to boiler feedwater, removes dissolved oxygen , By acting as an Oxygen Treatment Scavanger.
Benefits:- By Control of corrosive oxygen from boiler water which causes corrosion and pitting ,It improves boiler system long life and reliability .
In boiler feedwater conditioning RXSOL-40-5023-210 is fed to a boiler to remove dissolved oxygen and thus prevent pitting. For the reaction between RXSOL-40-5023-210 and oxygen to proceed rapidly and completely, it is necessary to maintain an excess sulfite concentration at an elevated temperature.
The use of RXSOL-40-5023-210 as a chemical deoxygenator is economical within certain limitations imposed by the dissolved oxygen content of the feedwater. If appreciable quantities of dissolved oxygen are permitted to enter the boiler, costs will be high if RXSOL-40-5023-210 is relied on as the sole means of oxygen removal. Generally, costs are balanced by removal of as much of the oxygen as feasible by mechanical means, e.g. deaerator and by using RXSOL-40-5023-210 to react with the residual oxygen.
To prevent corrosion and pitting in feed lines, closed heaters and economizers, it is desirable to feed the RXSOL-40-5023-210 continuously to the boiler feedwater rather than directly to the boiler feedwater rather than directly to the boiler. Reaction between RXSOL-40-5023-210 and oxygen is not instantaneous and the completion of the reaction is aided by the longer contact times provided by feeding RXSOL-40-5023-210 to the feedwater.
Catalyzed RXSOL-40-5023-210 will, however, react almost instantaneously with dissolved oxygen even at cold water temperatures. Because of this property, catalyzed RXSOL-40-5023-210 has found increased use in the treatment of cooling water, process water, distribution system, etc. for preventing oxygen corrosion.
Theoretically, 7.88 pounds of RXSOL-40-5023-210 are required to remove one pound of oxygen. The efficiency of the oxygen removal is estimated at 75 per cent to allow for oxidation in contact with air, blowdown losses, etc. Therefore it is estimated that 10 pounds of RXSOL-40-5023-210 are required for each pound of oxygen removed (or 10 ppm RXSOL-40-5023-210 per 1 ppm dissolved oxygen.)
BENEFITS -
RAPID REACTION :
The catalyst RXSOL-40-5023-210 speeds up the removal of dissolved oxygen. Oxygen can be removed completely even from cold water due to catalytic action. Normal reaction time is as low as 15 to 20 seconds as against 10 to 30 minutes for uncatalysed sulphite.
EASY TO HANDLE :
RXSOL-40-5023-210 is a free flowing powder. It is soluble in water even at lower feed water temperature.It is non-toxic and non-corrosive and, therefore, can be handled easily.
pH CONTROL :
RXSOL-40-5023-210 is formulated to get proper pH control for optimum availability of catalyst for rapid oxygen removal.
COST EFFECTIVE :
The catalytic action reduces the excessive requirement of sulphite in feed water for the rapid removal of oxygen. Thus the quantity required is lower, making RXSOL-40-5023-210 treatment cost effective.
APPLICATION AND DOSAGE :
RXSOL-40-5023-210 solution should be dosed continuously. Dissolve the required quantity of RXSOL-40-5023-210 gently in boiler feed water in a separate tank. Dose this solution continuously in the boiler feed water line after the deaerator.
Above 8 ppm of sodium sulphite is required for the removal of 1 ppm of dissolved oxygen from boiler
feed water. About 10% to 20% of excess sulphite should be dosed to provide oxygen consuming reserve.
The table below gives the approximate dosage.
| Feed Water Temperature | RXSOL-40-5023-210 dosage in gms per ton ofsteam generation |
|
More than 80oC |
15 |
| 60 to 80oC | 30 |
| 40 to 60oC | 60 |
| Less than 40oC | 100 |
The rmax will provide technical assistance in arriving at optimum dosages for your operating conditions and requirements and in selecting a suitable dosing system for your plant
TEST METHOD ::: http://rxmarine.com/hydrazine-test-kit
HANDLING, STORAGE AND PRECAUTIONS :
RXSOL-40-5023-210 is mildly alkaline in nature. Normal precautions should be taken while handling solid powders. In case of contact, wash with water. Do not swallow.
RXSOL-40-5023-210 should be stored in a dry condition. Close the container tightly to avoid contact with air.
PACKING :
RXSOL-40-5023-210 is available in 50 kg polythene lined bags.
Oxygen Treatment Scavanger

| Product Name | Oxygen Treatment Scavanger (Powder) |
| Product Type | RXSOL-40-5023-210 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla , Hazira, Mumbai, Chennai, Vizag, Kolkata, UAE, OMAN , CANADA, Nairobi KENYA
| Phone | +91 22 20871200- 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

| Name of Substance | Cas Number | EC Number | Wight % |
| Sodium Sulfite | 7757-83-7 | 215-211-5 | 80 - 100% |
| Sodium Bisulfite | 7631-90-5 | 231-548-0 | 1.00 - 5.00% |
| Catalyst | Proprietory | NA | 5.00 -10.00% |

| Signal Word | Warning |
| Hazard Statements |
H302 Harmful if swallowed. H315 Causes skin irritation. |
| Precautionary statements - prevention | P280 Wear protective gloves. |
| Precautionary statements - response |
P302 + P352 IF ON SKIN: Wash with plenty of soap and water. |

| EYE CONTACT : | Immediately flush with plenty of water for at least 15 minutes. Get medical attention. |
| SKIN CONTACT : | Immediately flush with plenty of water for at least 15 minutes. If skin irritation persists, obtain medical attention. |
| INGESTION : | Do not induce vomiting without medical advice. If conscious, washout mouth and give water to drink. If unconsious,do not give anything by mouth, place in the recovery position, check breathing and pulse. If necessary give artifical respiration. Get medical attention. |
| INHALATION : | Remove to fresh air, treat symptomatically. If breathing has stopped, trained personnel should begin artificial respiration or, if the heart has stopped, cardiopulmonary resuscitation (CPR) immediately. Get medical attention. |
| NOTE TO PHYSICIAN : | Based on the individual reactions of the patient, the physician's judgement should be used to control symptoms and clinical condition. |

| FLASH POINT : | Not flammable |
| LOWER EXPLOSION LIMIT : | Not flammable |
| UPPER EXPLOSION LIMIT : | Not flammable |
| EXTINGUISHING MEDIA : | Use extinguishing media appropriate for surrounding fire. |
| FIRE AND EXPLOSION HAZARD : | May evolve oxides of sulfur (SOx) under fire conditions. May evolve hydrogen sulfide (H2S) under fire conditions. |
| SPECIAL PROTECTIVE EQUIPMENT FOR FIRE FIGHTING : | May evolve oxides of sulfur (SOx) under fire conditions. May evolve hydrogen sulfide (H2S) under fire conditions. |

|
PRECAUTIONS : |
Restrict access to area as appropriate until clean-up operations are complete. Do not touch spilled material. Ventilate spill area if possible. Stop or reduce any leaks if it is safe to do so. Use personal protective equipment recommended in Section 8 (Exposure Controls/Personal Protection). Notify appropriate government, occupational health and safety and environmental authorities. |
|
METHODS FOR CLEANING UP : |
SMALL SPILLS: Soak up spill with absorbent material. Place residues in a suitable, covered, properly labeled container. Wash affected area. |
| ENVIRONMENTAL PRECAUTIONS: |
Do not contaminate surface water. |

| HANDLING : | Do not take internally. Avoid generating aerosols and mists. Do not get in eyes, on skin, on clothing. |
| STORAGE CONDITIONS : | Store in a cool well ventilated area away from direct sunlight. Store the containers tightly closed. Evolves sulfur dioxide (SO2) when open to atmosphere. The rate of SO2 evolution increases with temperature and/or transfer of product. Sulfur dioxide may react with vapors from neutralizing amines and may form a visible cloud of amine salt particles. |

| Engineering Control | Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit. | ||||||||
| Personal Protection |
Eye/face Protection: Wear appropriate protective eyeglasses or chemical safety goggles as described by OSHA's eye and face protection regulations in 29 CFR 1910.133 or European Standard EN166. Skin and body protection: Wear appropriate protective gloves and clothing to prevent skin exposure. Respiratory Protection : Follow the OSHA respirator regulations found in 29 CFR 1910.134 or European Standard EN 149. Use a NIOSH/MSHA or European Standard EN 149 approved respirator exposure limits are exceeded or if irritation or other symptoms are experienced. |
||||||||
| Other Protection Measure | Handle in accordance with good industrial hygiene and safety practice. | ||||||||
| Exposure Limit |
OCCUPATIONAL EXPOSURE LIMITS : ACGIH/TLV :Substance(s)
OSHA/PEL :Substance(s)
|

| PHYSICAL STATE | Crystaline or powder |
| APPEARANCE | Off-white |
| ODOR | Odorless |
| ODOR THRESOLD | Not determined |
| RELATIVE DENSITY | 2.60 |
| pH 1% SOLUTION | ≥ 7 |
| SOLUBILITY IN WATER | Soluble |
| BOILING POINT | Not applicable |
| VAPOR PRESSURE | Not applicable |
| VAPOR DENSITY | Not applicable |
| EVAPORATION RATE | Not applicable |
| FLASH POINT | Not flammable |
| AUTOIGNITION TEMPERATURE | Not applicable |
| UPPER FLAME LIMIT | Not applicable |
| LOWER FLAME LIMIT | Not applicable |
| DECOMPOSITION TEMPERATURE | Not determined. |
| FLAMMABILITY (SOLID,GAS) | Not flammable |
| OSHA FLAMMABILITY CLASS | Not applicable. |

| STABILITY : | Stable under normal conditions. |
| HAZARDOUS POLYMERIZATION : | Hazardous polymerization will not occur. |
| CONDITIONS TO AVOID : | High temperatures |
| MATERIALS TO AVOID : | Contact with strong oxidizers (e.g. chlorine, peroxides, chromates, nitric acid, perchlorate, concentrated oxygen,permanganate) may generate heat, fires, explosions and/or toxic vapors. Contact with strong acids(e.g.sulfuric,phosphoric,nitric,hydrochloric, chromic, sulfonic) may generate heat, splattering or boiling and toxic vapors |
| HAZARDOUS DECOMPOSITION PRODUCTS : | Under fire conditions: Oxides of sulfur, Hydrogen sulfide (H2S) |

No toxicity studies have been conducted on this product.
| SENSITIZATION : | HUMAN HAZARD CHARACTERIZATION : |
| CARCINOGENICITY : | None of the substances in this product are listed as carcinogens by the International Agency for Research on Cancer (IARC), the National Toxicology Program (NTP) or the American Conference of Governmental Industrial Hygienists (ACGIH). |
| HUMAN HAZARD CHARACTERIZATION : | Based on our hazard characterization, the potential human hazard is: Low |

| ECOTOXICITY |
Daphnia magna LC50 48 hrs 440 mg/L Western Mosquitofish 96hrs LC50 460 mg/L Biological Oxygen Demand (BOD) 0.12 lb/lb, instantaneous |
| PERSISTENCE AND DEGRADABILITY | No data available. |
| Products Biodegradation: | No data available. |
| BIOACCUMULATIVE POTENTIAL | No data available. |
| MOBILITY IN SOIL | No data available. |
| OTHER ADVERSE EFFECTS | No data available. |

| Waste treatment Method | Waste material must be disposed of in accordance with the national and local regulations. Leave chemicals in original containers. No mixing with other waste. Handle uncleaned containers like the product itself |

LAND TRANSPORT :
| Proper Shipping Name : | PRODUCT IS NOT REGULATED DURING TRANSPORTATION |
AIR TRANSPORT (ICAO/IATA) :
| Proper Shipping Name : | PRODUCT IS NOT REGULATED DURING TRANSPORTATION |
MARINE TRANSPORT (IMDG/IMO) :
| Proper Shipping Name : | PRODUCT IS NOT REGULATED DURING TRANSPORTATION |

| OSHA HAZARD COMMUNICATION RULE, 29 CFR 1910.1200 |
Based on our hazard evaluation, the following substance(s) in this product is/are hazardous and the reason(s) is/are shown below.
|
||||
| CERCLA/SUPERFUND, 40 CFR 117, 302 | Notification of spills of this product is not required. | ||||
| WHMIS (Canada) | CLASS C: Oxidizing material. | ||||
|
SARA 313 TOXIC CHEMICALS |
The following ingredients are SARA 313 "Toxic Chemicals" and may be subject to annual reporting requirements. CAS numbers and weight percents are found in Section 2. |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if RX Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |