It is highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver as an alternative to using hazardous acids for concrete removal. Back-Set is a one-of-a-kind formula. It uses an active ingredient found in sugar cane syrup, and is completely biodegradable.
RXSOL-22-2202-025 turned this vulnerability into an opportunity. "Back-Set" safely removes hardened concrete from a variety of difficult to clean surfaces. It break down the ionic bond in portland cement, releasing the cement from any surface to which it has adhered.
This liquid mixture specifically designed to deal with hard cases of cement cargo deposits or dry cement stains. Its proven advantage is the provision of immediate penetration and complete dissolution of cement, the result being a thorough cleaning.
Chemically Back-Set converts the positive ions in the hardened matrix into negative ions, which dissolves the cement into mud that can be rinsed away. Because it works chemically, rather than mechanically, Back-Set may be used to remove cured concrete, mortar, grout, and stucco from virtually any surface without harm.
The hardened concrete is saturated with Back-Set, either with a brush or by spraying. After 15-20 minutes, the area is again saturated with the chemical. The concrete typically begins to soften in 20-30 minutes, and can be rinsed off with water.
Excellent , concentrated and very effective cement remover with powerfull dissolving properties used on cement and bulk carriers.
The hardened concrete is saturated with Back-Set, either with a brush or by spraying. After 15-20 minutes, the area is again saturated with the chemical. The concrete typically begins to soften in 20-30 minutes,and can be rinsed off with water.The amount required for dosage can be obtained BY knowing the deposition composition as well as nature of cement to be removed.5 to 20 % recommended .These are recommended values based on experience. For optimum results dose RXSOL-22-2202-025 directly to the surface .
The amount required for dosage can be obtained BY knowing the deposition composition as well as nature of CEMENT to be removed . 5 to 20 % recommended .These are recommended values based on experience.
For optimum results dose RXSOL-22-2202-025 directly to the surface
Undiluted : In cases where we deal with heavy deposit build–up, CEMENT REMOVER must be applied undiluted.
Diluted : In cases of light deposition, on large surface areas, a solution between 10–40% may be used.
B. Cleaning Procedure
Undiluted/Diluted: In parts such as corner cavities, tank skeleton inlets, etc, Apply RXSOL-22-2202-025 through hard brush, mop, sponge or any other manual method. Let it soak for 15 minutes. Afterwards, wash thoroughly by applying high–pressure water source. In case of deposit persistence, repeat the cleaning procedure.
Refer to technical datasheet.
METHOD :::
1.For heavy deposition and thick layers of cement, a concentrated and stronger cleaner will be necessary to cut through the layers of cement.
2.Use a scraper, metal scrubber or flat head screwdriver to remove as much of the cement as possible.
3.For the remaining cement, apply this chemical
4.Once the cement loosens, scrub the area with a scrubber until it is all removed from the surface.
5.Rinse the area well with clean water.
6.Clean the area with alkaline soap and water
7.Flush system completely.
Other Valuable Hold Cleaners :::
Cement Remover RX Hold ::: Highly concentrated and powerful penetrating agents materials which is effectively react with cement to loosen the bonding strength . Best results can obtain on dry surface of cement. RXSOL'S R & D has developed this molecular cement dissolver. Part No.- RXSOL-22-2202-025, Part No.- RXSOL-22-2202-020, Part No.- RXSOL-22-2202-050

| Product Name | RXSOL-22-2202-210 |
| Product Type | CEMENT REMOVER RX HOLD |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Fujairah, Muscat
| Phone | +91 22 27815541 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
|
Proprietory Blend |
20-40 |
........................ |
...................... |
34, 37 |
C |
|
Corrosion Inhibitor |
5-10 |
NA |
NA |
NA |
- |
| Capryliminodipropionate | 6-8 | ||||
| Hordaphos MDGB Phosphate ester, Clariant AG | 5-9 | ||||
| Phosphoric Derivative | 11-18 |
*See Section 16

|
Odour |
Strong smell of hydrogen chloride. |
|
Appearance |
Liquid, pale yellow, soluble in water. |
|
Contact with eyes |
Can cause damage to the eyes. |
|
Contact with skin |
Prolonged skin or eye contact may cause chemical burns. |
|
Inhalation |
Causes severe irritation, May cause breathing difficulty. |
|
Ingestion |
Not regarded as a potential route of exposure.,Causes burning sensatio. |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Seek medical advice if necessary Contaminated clothing should be laundered before use |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15minutes.Irrigate eyes thorough lywhilst lifting eyelids Can cause damage to the eyes Obtain immediate medical attention |
|
Ingestion |
Do not induce vomiting Never give anything by mouth to anunconscious person.Give plenty of water to drink Obtain immediate medical attention |
|
Inhalation |
Remove patient to fresh air Seek medical attention if ill effects.occur |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) |

-Non combustible
-Smoke from fires is corrosive, Hydrogen chloride may be formed
-Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
-Substance evolves toxic fumes, wear self-contained breathing apparatus
-Use water spray or fog to knock down and absorb corrosive fumes

|
Personal Precautions |
Wear protective clothing as persection8. |
|
Environmental Precautions |
Do not allow to enter public sewers and water courses. |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. |
|
Special Precautions |
Wear protective clothing as persection 8. |

|
Handling |
Avoid contact with skin and eyes(S24/25) Do not breathe vapour/fumes(S23) Eye wash bottles should be available Wear protective clothing as per section8 Ensure adequate ventilation Inuse, may form flammable/explosive vapour-air mixtur(R18) |
|
Storage |
Keep only in the original container in a cool, well ventilated place(S3/9/49) Keep in acid store |

|
Exposure Limits |
TLV(TWA)1mg/m3(HCl). |
|
Exposure controls |
The undiluted product must not be used in a confined space with out good ventilation. |
|
Occupational exposure controls |
Wear suitable protective clothing, including eye/face protection and gloves(plastic or rubber are recommended) Respiratory protectionmay be required under exceptional circumstances when excessive air contamination exists Eye wash bottles should be available. |
|
|
|

|
Odour |
Pungent smell |
|
Appearance |
Liquid, pale yellow, soluble in water |
|
PH |
1.5at 100%concentration |
|
Boiling point |
~100°Cat 760mm/Hg |
|
Vapour pressure |
105.5at 20degC |
|
Vapour density |
(air=1)1.26 |
|
Freezing point |
~-30°Cat 760mm/Hg |
|
soluble in water |
Completely soluble in water |
|
Specific gravity |
(water=1)1.16 |
|
Non combustible |
|

This articleis considered stable under normal conditions, In use, may form flammable / explosive vapou r-airmixture(R18), Reaction products
may include hydrogen.Avoid over heating.In compatible with alkalis(strong bases).Contact with nitrite(e.g. Diesel guard NB, Cooling Water treatment)
liberates toxic gas.

|
Toxico logical information |
Prolonged skin or eye contact may cause chemical burns. |
|
Inhalation |
Can cause damage to the respiratory system. |
|
Contact with skin |
Prolonged skin or eye contact may cause chemical burns. |
|
Contact with eyes |
Prolonged skin or eye contact may cause chemical burns. |
|
Ingestion |
Can cause damage to the digestive system. |
|
Carcinogenicity |
No evidence of carcinogenic effects. |

|
Ecotoxicity |
This product contains watersoluble and bio degradable composition. |
|
Mobility |
Emulsifies in water. |
|
Persistence and Biodegradability |
Most components in this product are not readily biodegradable. |
|
Bioaccumulation Potential |
Hydrocarbon solvents have the potential to bioaccumilate. |
|
Other Adverse Effects |
No environmental problems are expected when the product is used / handled correctly.In its intended use, the product will not be released into the environment. |

|
Classification |
This material and/or its container must be disposed of as disposal waste procedure. |
|
Disposal considerations |
Obtain the consent of pollution control authorites before discharging to waste water treatment plants(S54) Disposl should be in accordance with local, state or national legislation |

| Proper Shipping Name | ||||
| UN | ||||
| Proper Shipping Name | Acidic solution | |||
| UN NO. |
1789 |
|||
| Hazard Class | 8 | PackingGroup | II | |
|
Road/Rail(ADR/RID) |
||||
| Proper Shipping Name |
Acidic solution |
|||
| ADR UN No. |
1789 |
|||
|
ADRHazardClass |
8 | Tremcard |
80GC1789-II |
|
| Sear (IMDG) | ||||
| Proper Shipping Name |
Acidic Solution |
|||
| IMDG UN No. |
1789 |
|||
| IMDG Hazard Class | 8 | ICAO PackingGroup |
II |
|
| IMDG EmS | F-A, S-B | IMDG subrisk |
N/A |
|
|
IMDG Labels |
8 |
IMDG Flashpoint |
N/A |
|
|
Air(ICAO/IATA) |
||||
| ProperShippingName |
Acidic solution |
|||
| IMDG UNNo |
1789 |
|||
| IMDG HazardClass | 8 | IMDG PackGroup |
II |
|
| ICAO subrisk | N/A | ICAO Labels |
8+CAO |
|
| ICAO Flashpoint |
N/A |
|||
|
DOT/ CFR(USDepartment ofTransportation |
||||
|
DOTProperShippingName |
Acidic solution |
|||
|
HazardousMaterial |
Acidic Solution |
|||
| HazardClass | 8 | IdentificationNumber: | UN1789 | |
|
Product RQ (lbs) |
N/E | DOTsubrisk |
N/A |
|
|
DOTLabels |
8 |
DOTFlashpoint | N/A | |
- Forbiddenonpassengeraircraft

|
Risk Phrases |
Causes burns(R34) Irritating to respiratory system(R37) |
|
Safety Phrases |
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice(S26). Wear suitable protective clothing, eye/face protection and gloves(S36/37/39) In case of accident or if you feel un well, seek medical advice immediately (show the label where possible)(S45) |

Text of R and S phrase codes used in this safety data sheet:
|
R34 |
Causes burns; |
|
R37 |
Irritating to respiratory system |
|
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituent The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's propertiesThe data given here only applies when product used for proper applicat-ion(s).The product is not sold as suitable. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
|