Cement Remover Advance is a specially formulated heavy-duty acid-based cleaner designed to remove stubborn cement, concrete, grout, and lime deposits from metal, plastic, and painted surfaces. Unlike ordinary cement removers that rely solely on mineral acids, Cement Remover Advance incorporates a dual modified acid system together with corrosion inhibitors, dispersing agents, and surfactants. This ensures powerful cleaning action while offering maximum safety to equipment and surfaces.
The formulation provides deep penetration into porous deposits, dissolving hardened cement and scale effectively. Added surfactants and dispersing agents help to remove oily/greasy residues, ensuring a complete cleaning action in a single step.
Cement Remover ADVANCE is also available in gel form for vertical surfaces and walls, ensuring longer contact time and improved efficiency.
Safely and effectively removes even the most difficult temporary cements from common dental surfaces.
Typical Applications of Cement Remover Advance
- Removal of cement and concrete deposits from construction equipment, mixers, trucks, and scaffolding.
- Cleaning of tiles, floors, and walls after construction.
- Dissolving hardened mortar and grout from tools, molds, and shutters.
- Removal of lime and scale deposits from cooling systems, boilers, and pipelines.
- Heavy-duty descaling of industrial surfaces exposed to concrete splashes.
Key Features of Cement Remover Advance
- Fast and Effective: Quickly dissolves cement, mortar, and lime scale deposits.
- Dual Acid Power: It breaks down cement, while also enhancing silicate dissolution and reduces fuming.
- Corrosion Protection: Built-in inhibitors minimize metal attack, extending equipment life.
- Safe and Versatile: Compatible with steel, copper, brass, aluminum, plastics, and painted surfaces.
- Penetrating Action: Surfactants and chelating agents ensure deeper penetration and residue-free cleaning.
- Low Fuming & Safer Handling: Reduced acid mist compared to conventional hydrochloric acid cleaners.
- Optional Gel Form: Clings to vertical walls, providing superior cleaning efficiency. The gel form is another variant of this product which is extremely effective for vertical cleaning.
Frequently Asked Questions - Cement Remover Advance

| Product Name | RXSOL-10-3006-008 |
| Product Type | Cement Remover Advance Formula |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Stock Point : Mumbai, Kandla, Kolkata, Chennai, Visakhapatnam, Fujairah, Muscat
| Phone | +91 22 27815541 / 42 |
| Fax | +91 22 2781 1318 :::AOH :0091 9821214367 |
| mail@rxmarine.com |

|
Chemical Name |
Concentration |
CAS Number |
EC Number |
R Phrases* |
Symbols |
|
Proprietory Blend |
20-40 |
........................ |
...................... |
34, 37 |
C |
|
Corrosion Inhibitor |
5-10 |
NA |
NA |
NA |
- |
| Capryliminodipropionate | 6-8 | ||||
| Hordaphos MDGB Phosphate ester, Clariant AG | 5-9 | ||||
| Phosphoric Derivative | 11-18 |
*See Section 16

|
Odour |
Strong smell of hydrogen chloride. |
|
Appearance |
Liquid, pale yellow, soluble in water. |
|
Contact with eyes |
Can cause damage to the eyes. |
|
Contact with skin |
Prolonged skin or eye contact may cause chemical burns. |
|
Inhalation |
Causes severe irritation, May cause breathing difficulty. |
|
Ingestion |
Not regarded as a potential route of exposure.,Causes burning sensatio. |

|
Contact with skin |
Remove contaminated clothing immediately and drench affected skin with plenty of water. Seek medical advice if necessary Contaminated clothing should be laundered before use |
|
Contact with eyes |
If substance has got into eyes, immediately wash out with plenty of water for at least 15minutes.Irrigate eyes thorough lywhilst lifting eyelids Can cause damage to the eyes Obtain immediate medical attention |
|
Ingestion |
Do not induce vomiting Never give anything by mouth to anunconscious person.Give plenty of water to drink Obtain immediate medical attention |
|
Inhalation |
Remove patient to fresh air Seek medical attention if ill effects.occur |
|
General |
In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible) |

-Non combustible
-Smoke from fires is corrosive, Hydrogen chloride may be formed
-Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions
-Substance evolves toxic fumes, wear self-contained breathing apparatus
-Use water spray or fog to knock down and absorb corrosive fumes

|
Personal Precautions |
Wear protective clothing as persection8. |
|
Environmental Precautions |
Do not allow to enter public sewers and water courses. |
|
Clean Up Actions |
Absorb spillage in inert material and shovel up Ventilate the area and wash spill site after material pick-up is complete. |
|
Special Precautions |
Wear protective clothing as persection 8. |

|
Handling |
Avoid contact with skin and eyes(S24/25) Do not breathe vapour/fumes(S23) Eye wash bottles should be available Wear protective clothing as per section8 Ensure adequate ventilation Inuse, may form flammable/explosive vapour-air mixtur(R18) |
|
Storage |
Keep only in the original container in a cool, well ventilated place(S3/9/49) Keep in acid store |

|
Exposure Limits |
TLV(TWA)1mg/m3(HCl). |
|
Exposure controls |
The undiluted product must not be used in a confined space with out good ventilation. |
|
Occupational exposure controls |
Wear suitable protective clothing, including eye/face protection and gloves(plastic or rubber are recommended) Respiratory protectionmay be required under exceptional circumstances when excessive air contamination exists Eye wash bottles should be available. |
|
|
|

|
Odour |
Pungent Smell |
|
Appearance |
Liquid, Pale Yellow, soluble in water |
|
PH |
1.5at 100%concentration |
|
Boiling point |
~100°Cat 760mm/Hg |
|
Vapour pressure |
105.5at 20degC |
|
Vapour density |
(air=1)1.26 |
|
Freezing point |
~-30°Cat 760mm/Hg |
|
soluble in water |
Completely soluble in water |
|
Specific gravity |
(water=1)1.16 |
|
Non combustible |
|

This articleis considered stable under normal conditions, In use, may form flammable / explosive vapou r-airmixture(R18), Reaction products
may include hydrogen.Avoid over heating.In compatible with alkalis(strong bases).Contact with nitrite(e.g. Diesel guard NB, Cooling Water treatment)
liberates toxic gas.

|
Toxico logical information |
Prolonged skin or eye contact may cause chemical burns. |
|
Inhalation |
Can cause damage to the respiratory system. |
|
Contact with skin |
Prolonged skin or eye contact may cause chemical burns. |
|
Contact with eyes |
Prolonged skin or eye contact may cause chemical burns. |
|
Ingestion |
Can cause damage to the digestive system. |
|
Carcinogenicity |
No evidence of carcinogenic effects. |

|
Ecotoxicity |
This product contains watersoluble and bio degradable composition. |
|
Mobility |
Emulsifies in water. |
|
Persistence and Biodegradability |
Most components in this product are not readily biodegradable. |
|
Bioaccumulation Potential |
Hydrocarbon solvents have the potential to bioaccumilate. |
|
Other Adverse Effects |
No environmental problems are expected when the product is used / handled correctly.In its intended use, the product will not be released into the environment. |

|
Classification |
This material and/or its container must be disposed of as disposal waste procedure. |
|
Disposal considerations |
Obtain the consent of pollution control authorites before discharging to waste water treatment plants(S54) Disposl should be in accordance with local, state or national legislation |

| Proper Shipping Name | ||||
| UN | ||||
| Proper Shipping Name | Acidic solution | |||
| UN NO. |
1789 |
|||
| Hazard Class | 8 | PackingGroup | II | |
|
Road/Rail(ADR/RID) |
||||
| Proper Shipping Name |
Acidic solution |
|||
| ADR UN No. |
1789 |
|||
|
ADRHazardClass |
8 | Tremcard |
80GC1789-II |
|
| Sear (IMDG) | ||||
| Proper Shipping Name |
Acidic Solution |
|||
| IMDG UN No. |
1789 |
|||
| IMDG Hazard Class | 8 | ICAO PackingGroup |
II |
|
| IMDG EmS | F-A, S-B | IMDG subrisk |
N/A |
|
|
IMDG Labels |
8 |
IMDG Flashpoint |
N/A |
|
|
Air(ICAO/IATA) |
||||
| ProperShippingName |
Acidic solution |
|||
| IMDG UNNo |
1789 |
|||
| IMDG HazardClass | 8 | IMDG PackGroup |
II |
|
| ICAO subrisk | N/A | ICAO Labels |
8+CAO |
|
| ICAO Flashpoint |
N/A |
|||
|
DOT/ CFR(USDepartment ofTransportation |
||||
|
DOTProperShippingName |
Acidic solution |
|||
|
HazardousMaterial |
Acidic Solution |
|||
| HazardClass | 8 | IdentificationNumber: | UN1789 | |
|
Product RQ (lbs) |
N/E | DOTsubrisk |
N/A |
|
|
DOTLabels |
8 |
DOTFlashpoint | N/A | |
- Forbiddenonpassengeraircraft

|
Risk Phrases |
Causes burns(R34) Irritating to respiratory system(R37) |
|
Safety Phrases |
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice(S26). Wear suitable protective clothing, eye/face protection and gloves(S36/37/39) In case of accident or if you feel un well, seek medical advice immediately (show the label where possible)(S45) |

Text of R and S phrase codes used in this safety data sheet:
|
R34 |
Causes burns; |
|
R37 |
Irritating to respiratory system |
|
The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituent The data given here is based on current knowledge and experience. This Safety Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's propertiesThe data given here only applies when product used for proper applicat-ion(s).The product is not sold as suitable. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
|