Boiler Coagulant

A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers. Boiler Coagulant prevents the formation of deposits on boiler internal surfaces.

RXSOL-50-5003-020 is a Liquid sludge conditioner designed to prevent deposits. A concentrated solution of surface-active polymers which is use as an internal sludge conditioners in boilers.

Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed by normal blow down. In this way tube overheating due to deposits is avoided. The treatment is primarily used in conjunction with Hardness Control, but also with other Rxsol chemical treatments. Boiler Coagulant can also be used where minor oil contamination has been experienced, the oil being required to be coagulated for removal by blow down. However, it must be noted that if oil contamination is continuous and excessive, off-line cleaning will be required. The source of oil contamination must be stopped immediately.

 

Application

RXSOL-50-5003-020 Boiler Coagulant prevents the formation of deposits on boiler internal surfaces. Sludge is kept dispersed in small particles and conditioned to be removed normal blow down. In this way tube over heating due to deposits is avoided. 

Dose

The initial dosage is 20 ml of treatment daily for every ton of boiler capacity. Bottom blow down is required daily when using Boiler Coagulant.

For optimum results dose Boiler Coagulant directly to the boiler via the bypass pot-feeder. Boiler Coagulant is compatible with any Rxsol Boiler Water Treatment and dosing can be combined. Dosage and control The initial dosage is 20 ml of treatment daily for every ton of boiler capacity. Daily bottom blow down is required when using Boiler Coagulant.

Technical specifications

Appearance

LIQUID

Color

AMBER

AMBER

9

Density

1.2

Note
  • Liquid product, easy to feed.
  • Prevents the formation of adherent deposits and sledges in boilers.
  • Keeps sludge dispersed for efficient removal by blow down.
  • Keeps boilers clean and extends boiler operational time between cleaning.
  • Used in conjunction with any products in Rxsol range of boiler water treatments.
  • Used to coagulate small amounts of oil which have contaminated the boiler water.
Remarks / Precaution

Packing sizes
25 ltr., 210 ltr.
MSDS

 

Product Name : RXSOL-50-5003-020
Product Type : BOILER COGULANT

Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA 

Stock Point : Mumbai, Kandla, Kolkata, Chennai, Vizag, Fujairah, Muscat, Nairobi

Phone : +91 22 65113333 / 5555 / 9999 / 27611360
Fax : +91 22 2781 1318 :::AOH :0091 9821214367
Email : mail@rxmarine.com

Chemical Name

Concentration

CAS Number

EC Number

R Phrases*

Symbols 

Sodium acrylate

5-10

25085-02-3

N/A

 -

Non classified ingredients

>90

 

 

 

 

*See Section 16

Odour

Odourless

Appearance

Liquid, Pale Yellow, soluble in water

Contact with eyes

Mildly irritating to eyes

Contact with skin

In cases of severe exposure, irritation may develop

Inhalation

Vapours or aerosols may cause irritation of eyes, nose and respiratory tract

Ingestion

May cause gastro-intestinal disturbances

Contact with skin

Remove contaminated clothing immediately and drench affected skin with plenty of water. The wash with soap and water.Seek medical attention if irritation persists.

Contact with eyes
 

If substance has got into eyes, immediately wash out with plenty of water for at least 15 minutes.Seek medical attention if irritation persists.

Ingestion

Never make an unconscious person vomit or drink fluids.Give water or milk to drink.When in doubt or symptoms persist, seek medical attention

Inhalation

Inhalation is unlikely to occur.Remove patient to fresh air.

General

In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).

-   Non combustible
-   None
-   Not flammable. In case of fire use extinguishing media appropriate to surrounding conditions

Precautions

Wear protective clothing as per section 8

Immediate Actions

Shut off source of leak if safe to do so

Clean Up Actions

Flush spill area with copious amounts of water

Special Precautions

Wear protective clothing as per section 8 No special precautions are required for this product

 Handling

The usual precautions for handling chemicals should be observed

 Storage

Keep only in the original container in a cool, well ventilated place (S3/9/49) Protect from frost

Exposure Limits

There are no recommended or established controls for this product.

Exposure controls

No special precautions are required for this product.

Occupational exposure controls

Wear suitable protective clothing, including eye/face protection and gloves (plastic or rubber are recommended).

gloves              suit             goggles

Gloves                       Suit                  Goggles

Odour

Odourless

Appearance

Liquid, pale yellow, soluble in water

pH

8.5 - 10 at 100 % concentration

Boiling point >

100 °C at 760 mm /Hg

Vapour pressure -

not known

Freezing point

 0 °C at 760 mm/Hg

Completely soluble in water

 

Specific gravity (water=1)

1.04

Non combustible

 

No hazardous decomposition products known . Avoid overheating, Keep away from frost.

Toxicological information

LD50 (dermal) : > 10000  mg/kg

Inhalation

Inhalation is unlikely to occur

Contact with skin

 In cases of severe exposure, irritation may develop

Contact with eyes

In cases of severe exposure, redness and irritation may develop

Ingestion

May cause gastro-intestinal disturbances

Carcinogenicity

No evidence of carcinogenic effects

Ecotoxicity

LC50 (bluegill sunfish)4750 mg/l(96 hr) (Sodium acrylate)

Mobility

Completely soluble in water

Persistence and Biodegradability

Most components in this product are not readily biodegradable. Sodium acrylate: Chemical oxygen demand (COD) 0.4 g/g Biological oxygen demand (BOD) 0.009 g/g

Bioaccumulation Potential

Bioaccumulation of the components in this product is insignificant.

Other Adverse Effects

Presents little or no hazard to the aquatic environment.

Classification

EU Waste class

Disposal considerations

Do not discharge into drains or the environment, dispose to an authorised waste collection point - Disposal should be in accordance with local, state or national legislation

Not classified as hazardous for transport

Classification and labelling

Not classified as hazardous for users

Risk Phrases

Not applicable

Safety Phrases

Not applicable

The information provided about the product on this Safety Data Sheet has been compiled from knowledge of the individual constituents The data given here is based on current knowledge and experience. This Safety  Data Sheet describes the product in terms of safety requirements and does not signify any warranty with regard to the product's properties The data given here only applies when product used for proper application(s). The  product is not sold as suitable for other applications - usage in such may cause risks not mentioned in this sheet. Do not use for other application(s) without seeking advice from manufacturerThis Safety Data Sheet is provided in compliance with The Dangerous Substances Directive (67/548/EEC)
This Safety Data Sheet is provided in compliance with The Dangerous Preparations Directive (88/379/EEC)
This Safety Data Sheet is provided in compliance with The Safety Data Sheets Directive (2001/58EC)

DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable.

Need a quote for this product?

Tell us the grade, packing and quantity you need — we ship across India and to major ports.

Request a quote office@kolkatachemical.com