| Porduct Name | Aluminum sulfate LIQ |
| Part Number | RXSOL-40-1904-270 |
Company Details:
RX MARINE INTERNATIONAL
105, A wing , BSEL , TECH PARK.
VASHI ,NEW BOMBAY 400703 INDIA
Branch : Kandla, Mumbai , Chennai, Vizag, Kolkata, UAE , OMAN , CANADA and KENYA
| Phone | +91 22 20871200 - 1400 |
| Fax | +91 22 27612100 :::AOH :0091 9821214367 |
| mail@rxmarine.com | |
| Website | www.rxmraine.com |

| Chemical Name | Cas No | EC No | Formula | Molecular weight |
| Aluminum sulfate LIQ | 10043-01-3 | 233-135-0 | Al2O12S3 | 342,15 g/mol |

| Signal Word | Danger |
| Hazard Statements |
H290 May be corrosive to metals. H318 Causes serious eye damage. |
| Precautionary statements |
P234 Keep only in original packaging. P280 Wear eye protection/ face protection. P305 + P351 + P338 IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. P390 Absorb spillage to prevent material damage. |
| Classification of the substance or mixture |
none |
| Other hazards | This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher. |

| General advice | Show this material safety data sheet to the doctor in attendance. |
| If inhaled | After inhalation: fresh air. |
| Eye Contact | After eye contact: rinse out with plenty of water. Immediately call in ophthalmologist. Remove contact lenses. |
| Skin Contact | In case of skin contact: Take off immediately all contaminated clothing. Rinse skin with water/ shower. |
| If swallowed | After swallowing: immediately make victim drink water (two glasses at most). Consult a physician. |
| Most important symptoms and effects, both acute and delayed | The most important known symptoms and effects are described in the labelling (see section 2.2) and/or in section 11 |
| Indication of any immediate medical attention and special treatment needed | No data available |

| Suitable extinguishing media | Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Unsuitable extinguishing media | For this substance/mixture no limitations of extinguishing agents are given. |
| Special hazards arising from the substance or mixture |
Sulfur oxides Aluminum oxide Not combustible. Ambient fire may liberate hazardous vapours. |
| Further information | Suppress (knock down) gases/vapors/mists with a water spray jet. Prevent fire extinguishing water from contaminating surface water or the ground water system |
| Advice for firefighters | In the event of fire, wear self-contained breathing apparatus. |

| Personal precautions, protective equipment and emergency procedures | Advice for non-emergency personnel: Avoid inhalation of dusts. Avoid substance contact. Ensure adequate ventilation. Evacuate the danger area, observe emergency procedures, consult an expert. For personal protection see section 8. |
| Enviromental Precaution | Do not let product enter drains. |
|
Methods and materials for containment and cleaning |
Cover drains. Collect, bind, and pump off spills. Observe possible material restrictions (see sections 7 and 10). Take up dry. Dispose of properly. Clean up affected area. Avoid generation of dusts.. |
| Reference to other sections | For disposal see section 13. |

| Precautions for safe handling | For precautions see section 2.2. |
| Conditions for safe storage, including any incompatibilities |
Storage conditions No metal containers. Tightly closed. Dry. hygroscopic Store under inert gas. Storage class Storage class (TRGS 510): 8B: Non-combustible, corrosive hazardous materials |
| Specific end use(s) | Apart from the uses mentioned in section 1.2 no other specific uses are stipulated |

| Engineering Control | Provide adequate general and local exhaust ventilation. Work in fume cupboard. Must not be handled in confined space without sufficient ventilation. |
| Eye/face protection | Use equipment for eye protection tested and approved under appropriate government standards such as NIOSH (US) or EN 166(EU). Tightly fitting safety goggles |
| Body Protection | protective clothing |
| Respiratory protection |
Our recommendations on filtering respiratory protection are based on the following standards: DIN EN 143, DIN 14387 and other accompanying standards relating to the used respiratory protection system. Recommended Filter type: Filter type P2
The entrepeneur has to ensure that maintenance, cleaning and testing of respiratory protective devices are carried out according to the instructions of the producer. These measures have to be properly documented.
|
| Control of environmental exposure | Do not let product enter drains. |

| Physical state | Powder |
| Colour | White |
| Odor | odorless |
| pH | No data available |
| Melting point/freezing point | Melting point/range: 770 °C - dec. |
| Initial boiling point and boiling range | 112 - 116 °C |
| Upper/lower flammability or explosive limits | No data available |
| Autoignition temperature | No data available |
| Viscosity |
Viscosity, kinematic: No data available Viscosity, dynamic: No data available |
| Density | 2,71 g/mL at 25 °C - lit. |
| Relative Density | No data available |
| Solubility | ca.0,00001 g/l at 21,5 °C - insoluble |

| Reactivity | No data available |
| Chemical stability | The product is chemically stable under standard ambient conditions (room temperature) . |
| Possibility of hazardous reactions | No data available |
| Conditions to avoid | Air Exposure to moisture. no information available |
| Incompatible materials |
No data available
|
| Hazardous product dicomposition | In the event of fire: see section 5 |

| Acute toxicity | LD50 Oral - Rat - male and female - > 2.000 mg/kg (OECD Test Guideline 401) Inhalation: No data available LD50 Dermal - Rabbit - male and female - > 5.000 mg/kg (OECD Test Guideline 402) |
| Skin corrosion/irritation | Skin - Rabbit Result: No skin irritation - 4 h (OECD Test Guideline 404) |
| Respiratory or skin sensitization | Local lymph node assay (LLNA) - Mouse Result: negative (OECD Test Guideline 429) |
| Serious eye damage/eye irritation | Eyes - Rabbit Result: Irreversible effects on the eye |
| Germ cell mutagenicity |
Test Type: Ames test Test system: Escherichia coli/Salmonella typhimurium Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 471 Result: negative Test Type: In vitro mammalian cell gene mutation test Test system: mouse lymphoma cells Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 476 Result: negative Test Type: Micronucleus test Test system: Human lymphocytes Metabolic activation: with and without metabolic activation Method: OECD Test Guideline 487 Result: negative Test Type: Micronucleus test Species: Rat Application Route: Oral Method: OECD Test Guideline 474 Result: negative Remarks: (in analogy to similar products) The value is given in analogy to the following substances: aluminium hydroxide Species: Rat Application Route: Oral Remarks: Cytogenetic analysis |

| Toxicity |
Toxicity to fish semi-static test LC50 - Danio rerio (zebra fish) - > 87,5 mg/l - 96 h (OECD Test Guideline 203) Toxicity to daphnia and other aquatic invertebrates static test EC50 - Daphnia magna (Water flea) - > 200 mg/l - 48 h (OECD Test Guideline 202) Toxicity to algae static test ErC50 - Pseudokirchneriella subcapitata (microalgae) - 0,24 mg/l - 72 h (OECD Test Guideline 201) Toxicity to bacteria static test EC50 - activated sludge - > 200 mg/l - 3 h (OECD Test Guideline 209) Toxicity to fish(Chronic toxicity) semi-static test NOEC - Salvelinus fontinalis (Brook trout) - 0,024 mg/l - 60 d Remarks: (ECHA) semi-static test NOEC - Salvelinus fontinalis (Brook trout) - 0,024 mg/l - 60 d Remarks: (ECHA) semi-static test NOEC - Salvelinus fontinalis (Brook trout) - 0,024 mg/l - 60 d Remarks: (ECHA) Toxicity to daphnia and other aquatic invertebrates(Chronic toxicity) semi-static test NOEC - Ceriodaphnia dubia (water flea) - 3,8 mg/l - 8 d (US-EPA) |
| Persistence and degradability | The methods for determining biodegradability are not applicable to inorganic substances. |
| Mobility in soil | Moderate mobility. |
| Results of PBT and vPvB assessment | Results of PBT and vPvB assessment This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher |
| Endocrine disrupting properties Product: Assessment | The substance/mixture does not contain components considered to have endocrine disrupting properties according to REACH Article 57(f) or Commission Delegated regulation (EU) 2017/2100 or Commission Regulation (EU) 2018/605 at levels of 0.1% or higher. |

| Waste treatment Method |
No data available |

| UN number |
ADR/RID: 3260 IMDG: 3260 IATA: 3260 |
| UN proper shipping name |
ADR/RID: CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate) IMDG: CORROSIVE SOLID, ACIDIC, INORGANIC, N.O.S. (aluminium sulfate) IATA: Corrosive solid, acidic, inorganic, n.o.s. (aluminium sulfate) |
| Transport hazard classess |
ADR/RID: 8 IMDG: 8 IATA: 8 |
| Packaging group | ADR/RID:III IMDG:III ICAO :III |
| Environmental hazards | No data available |

| Safety, health and environmental regulations/legislation specific for the substance or mixture |
Uk Regulatory References Chemicals (Hazard Information & Packaging) Regulations. Approved Code Of Practice Safety Data Sheets for Substances and Preparations. Classification and Labelling of Substances and Preparations Dangerous for Supply. Guidance Notes Workplace Exposure Limits EH40. EU Legislation Dangerous Substance Directive 67/548/EEC. Dangerous Preparations Directive 1999/45/EC. Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 with amendments. |
| Chemical Safety Assessment | No infomation |

| Other Information |
The information above is believed to be accurate and represents the best information currently available to us. However, we make no warranty of merchantability or any other warranty, express or implied, with respect to such information, and weassume no liability resulting from its use. Users should make their own investigations to determine the suitability of the information for their particular purposes. In no event shall be liable for any claims, losses, or damages of any third party or for lost profits or any special, indirect, incidental, consequential or exemplary damages, howsoever arising, even if Rx Marine International has been advised of the possibility of such damages. DISCLAIMER OF LIABILITY :The information in this SDS was obtained from sources which we believe are reliable. However, the information is provided without any warranty, express or implied, regarding its correctness. The conditions or methods of handling, storage, use or disposal of the product are beyond our control and may be beyond our knowledge. For this and other reasons, we do not assume responsibility and expressly disclaim liability for loss, damage or expense arising out of or in any way connected with the handling, storage, use or disposal of the product. This MSDS was prepared and is to be used only for this product. If the product is used as a component in another product, this MSDS information may not be applicable. |
| No data available |
| Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |
| Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. |