Corroision Inhibitor Multifunctional closed/chilled systems 20 Ltr

Placeholder

Corroision Inhibitor Multifunctional closed/chilled systems 20 Ltr

superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitor

Compare
SKU: RXSOL-40-4011-020 Category:

Corrosion Inhibitor Additives for Water system
This is a Highly effective INHIBITOR for closed loop , line chilled water with unique dual control of corrosion and scale from system.

This closed water treatment chemicals are  designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.
 

RXSOL-40-4011-020 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

 

 


 

 

Technical Bulletin

More about Corroision Inhibitor Multifunctional closed/chilled systems 20 Ltr

 

By using this corrosion inhibitor the build up of sediment deposits and damaging corrosion of water boilers is greatly reduced. Our research and experience recomend  to working water at a rate of 0.5 to 1.0 percent of the weight of water in the system. This amounts to 4 up to 8 Ltr corrosion inhibitor in 100 gallons of water.
 

RXSOL-40-4011-020 is a superior multifunctional, nitrite-based chemical treatment used for the control of corrosion in closed cooling systems and chilled water systems. RXSOL-40-4011-020 is a liquid product containing a combination of ferrous and non-ferrous corrosion inhibitors, a non-carbonate buffer, scale inhibitors, dispersants and a leak detection dye.

The recommended dosage of RXSOL-40-4011-020 is 15.6-23.4 l/m3 of system capacity or 60.6-87 RXSOL-40-4011-020 of system capacity in all systems. Clean up the system if the system becomes contaminated with iron. Maintain 600-750 ppm nitrite as NO2. RXSOL-40-4011-020  is intended for industrial use only. It should not be fed to potable water systems

Product Label

This closed water treatment chemicals are designed to treat hot and chilled water systems. The product contains a combination of nitrite, borate, and silicate formulated to minimize corrosion and deposition. The product comes in a clear and pink appearance form.

 

How Can we Help You
Send via WhatsApp